Adjustable wrench
Use it for: To loosen and tighten compression nuts and supply line connections.
Shop adjustable wrenchesTo replace a shutoff valve straight stop, turn off the main water, relieve pressure, remove the old valve, install a matching new valve, then slowly restore water and check for leaks.
This repair is usually worth doing when the valve drips from the body or stem, will not fully shut off, or is badly corroded. The key is matching the new valve to the existing pipe connection and outlet size before you take anything apart.
Before you start: Match the pipe connection type, outlet size, and shutoff orientation before ordering.

Use it for: To loosen and tighten compression nuts and supply line connections.
Shop adjustable wrenches
Use it for: To hold the valve body or pipe steady while you loosen fittings.
Shop tongue-and-groove pliers
Use it for: To catch water left in the line when the old valve comes off.
Find a drain pan or bucket
Use it for: To protect the cabinet or floor and wipe fittings dry for leak checks.
Shop absorbent shop towels
Use it for: To remove an old compression ferrule if it is stuck on the pipe.
Find a compression sleeve puller
Use it for: To trim damaged pipe end material if the old connection area is scarred or out of round.
Shop a tubing cutterAs an Amazon Associate I earn from qualifying purchases. Repair Riot may earn a commission at no extra cost to you.
If it works: You have confirmed the straight stop itself is the problem and you have a matching replacement in hand.
If it doesn’t: If the leak is coming from the supply tube nut or the faucet connection instead, tighten or replace that connection first rather than replacing the valve.
If it works: Water flow has stopped, pressure is relieved, and the work area is protected.
If it doesn’t: If water keeps running steadily after the main is off, the main shutoff may not be closing fully and this repair should wait until the water can be shut down reliably.
If it works: The old valve is off and the pipe end is exposed and ready to inspect.
If it doesn’t: If a compression sleeve or nut is stuck, use a compression sleeve puller instead of prying against the pipe.
If it works: The new straight stop is installed squarely on the pipe and tightened without twisting the stub-out.
If it doesn’t: If the nut will not start by hand or the valve will not seat fully, remove it and recheck the connection type and pipe condition before tightening further.
If it works: Water is back on, the fixture works, and the new valve stays dry at both connections.
If it doesn’t: If a connection seeps, tighten it a little more while supporting the valve body, then dry it again and recheck.
If it works: The valve operates normally, shuts water off when needed, and stays dry during real use.
If it doesn’t: If the valve works but a slow leak returns, disconnect and inspect the sealing surfaces or replace the affected supply connection.
Match the pipe connection type, outlet size, and shutoff orientation before ordering.
As an Amazon Associate I earn from qualifying purchases. Repair Riot may earn a commission at no extra cost to you.
A straight stop connects to a pipe that comes straight out toward the fixture. An angle stop is used when the pipe comes out of the wall and the outlet needs to turn upward. Match the shape of the old valve.
Sometimes a stem leak can be reduced by gently tightening the packing nut, but if the valve is old, seized, corroded, or will not shut off fully, replacing the whole valve is usually the more reliable fix.
Not on the compression seal itself. Compression fittings seal by the ferrule and mating surfaces, not by tape on the threads. Thread sealant is only used where the valve has a true threaded pipe connection that calls for it.
Use a compression sleeve puller if you have one. Avoid gouging the pipe with a saw or screwdriver. If the pipe end gets damaged, the new valve may not seal well.
It is better to use the new hardware that comes with the replacement valve when the connection style matches. Old compression parts may not seal well on a new valve.