Adjustable wrench
Use it for: To loosen and tighten compression nuts and supply line connections.
Shop adjustable wrenchesTo replace an under sink shutoff valve, first confirm the valve itself is leaking or no longer shuts off, then turn water off at the main, relieve pressure, remove the old valve, install the correct replacement, and test it under pressure.
This is a manageable repair if the valve is exposed and the pipe is in good shape. The key is buying the right valve for your pipe and connection style before you take anything apart.
Before you start: Match the pipe connection type, outlet size, and shutoff orientation before ordering.

Use it for: To loosen and tighten compression nuts and supply line connections.
Shop adjustable wrenches
Use it for: To hold the valve body or back up the pipe while you loosen fittings.
Shop tongue and groove pliers
Use it for: To catch water left in the line when the old valve comes off.
Find a drain pan
Use it for: To protect the cabinet and wipe fittings dry during leak checks.
Shop absorbent shop towels
Use it for: To remove an old compression ferrule if it will not come off cleanly.
Find a compression sleeve puller
Use it for: To inspect the pipe, valve connection, and cabinet for slow leaks.
Shop LED flashlightsAs an Amazon Associate I earn from qualifying purchases. Repair Riot may earn a commission at no extra cost to you.
If it works: You know the valve itself is leaking or failing to shut off, and you have a matching replacement valve.
If it doesn’t: If the leak is actually from the faucet supply line or the faucet above, replace that part instead of the shutoff valve.
If it doesn’t: If you see a slow drip at a compression connection, tighten it a little more while supporting the valve body, then dry and recheck.
If it works: The shutoff valve works normally in real use and the cabinet stays dry.
If it doesn’t: If the valve works but a supply line connection seeps, disconnect and inspect that connection for a damaged washer or mismatched fitting.
Match the pipe connection type, outlet size, and shutoff orientation before ordering.
As an Amazon Associate I earn from qualifying purchases. Repair Riot may earn a commission at no extra cost to you.
If water appears from the valve body, handle stem, or the valve will not shut water off to the faucet, the shutoff valve is the likely problem. If the leak is at the flexible tube or its nut, the supply line may be the part to replace.
Yes. You can replace only the failed valve as long as the other one works properly and the pipe is in good condition.
Not on compression connections. Compression fittings seal at the ferrule, not the threads. Threaded pipe connections may use a thread sealant, but only if that connection style calls for it.
Use a compression sleeve puller instead of prying or cutting carelessly. Damaging the pipe can turn a simple valve swap into a larger repair.
The most common causes are a slightly loose compression nut, a crooked connection, damaged pipe where the valve seals, or a mismatched replacement valve. Dry the area, pinpoint the exact source, and correct that connection before using the sink normally.